Part Number AM4RA3LC97DDU52301

Circuit Breaker

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
am4ra3lc97ddu52301
Demil:
Shelf Life:
UOM:
NIIN:
016205007

Part Information
Hydralic magnetic circuit breaker

NSN
National Stock Number:
5925-01-620-5007 5925016205007
TXT
Description:
Circuit Breaker
INC
INC
Item Name Code:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Multipole-multiple actuator type
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.00 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.00 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The center to center distance between terminals parallel to the width of the item.AEBQ
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
4
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
8 threaded stud
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
20
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes dc all locations
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
480.0 ac all locations
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Error current all locations
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Magnetic-hydraulic all locations
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay all locations
MRC:
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
120.0 all locations
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Nontrip free
MRC:
Indicates the type and number of actuators provided for manual control.CPRT
Manual Actuator Type And Quantity:
4 toggle
MRC:
The basic internal electrical configuration of the trip mechanism.CPSM
Internal Trip Release Configuration:
Series trip all locations
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.25 inches
MRC:
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
Trip Delay Time In Seconds Per Rated Continuous Current:
18.0 at 100 pct all locations
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 all locations
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 threaded stud

Similar Circuit Breakers

« Circuit Breakers Catalog
Compare Now »
Clear | Hide