Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Radar Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
15.600 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
19.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 108.0 volts and 121.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
Between 21.5 volts and 29.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 380.0 hertz and 420.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Altitude delay simulator; monitor unit; delay line; cable; cable-monitor assembly; waveguide horn
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum housing
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Altitude response, altitude tracking rate, rf power measurement
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Altitude simulation 150 ft and 750 ft +/-2 percent; altitude step function measured 10 +/- 0.1 second; radar power measurement 5 db; loop sensititivity above 125 db +/- 4 db; input power 108 v to 121 v single phase, 380 cycles to 420 cycles and 21.5 vdc to 29 vdc
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-9.3
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
15.500 inches
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
To 1f-111a-4-18 & 33a1-12-411-4
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set radar, except specially designed