Part Number AP17500339

Power Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
ap17500339
Demil:
No
Shelf Life:
UOM:
NIIN:
012014452
NSN
National Stock Number:
5950-01-201-4452 5950012014452
TXT
Description:
Power Transformer
INC
INC
Item Name Code:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Two phase to three phase single component
MRC:
Indicates the type of connecting windings in a transformer to be powered by two or three phase currents.ACZD
Transformer Winding Connection Type:
Scott
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 2.240 inches and 2.250 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 1.115 inches and 1.125 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 0.395 inches and 0.410 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.120 inches single mounting facility single center group and 1.130 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 secondary single component
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.80 ac pounds per hour wet single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.80 ac pounds per hour wet single component single secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 pin

Similar Power Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide