Part Number APM271-12

Special Scale Meter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
apm271-12
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
012991398

Part Information
Green led under and over voltage indication; confidential scale

NSN
National Stock Number:
6625-01-299-1398 6625012991398
TXT
Description:
Special Scale Meter
INC
INC
Item Name Code:
61955
INC
COM
Compliance:
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Dc
MRC:
The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
Dielectric Withstanding Voltage In Volts:
500.0
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.060 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.812 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.156 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 58.0 hertz and 420.0 hertz
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Shock resistant and vibration resistant
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
4.312 inches
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Bargraph
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Two hole/stud
MRC:
The rated sensitivity of the item.ANTG
Sensitivity Rating:
20.0 milliamperes
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
5.250 inches
MRC:
A measurement taken at right angles to the length of the meter body behind the mounting flange, in distinction from thickness.APSY
Meter Body Width Behind Mounting Flange:
3.750 inches
MRC:
The hue or tint of the background.AQFY
Background Color:
Black single indicator single range
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode
MRC:
None.BMNG
Meter Body Height Behind Mounting Flange:
0.730 inches
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Overranging and self-illumination facility
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1 pct of reading porm 1 digit single indicator single range
MRC:
The hue or tint of the display.CTQH
Display Color:
Red single indicator single range
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
6 threaded stud
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
Between 107.0 ac and 123.0 ac
MRC:
Markings included on an item for the purpose of offering instructions or warnings or to indicate the purpose,function,or application of the item.excludes manufacturers part numbers,symbols,or the like.MARK
Special Markings:
High voltage present, on warning label; test, at term.
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Illumination controlled by 0 to 5 vrms signal
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set, elect. Equip.

Similar Special Scale Meters

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »