Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Reference number breakdown: at8 product family; 06 number of output channels; 0 system operating software able; 1 front panel/programmer config is blank panel with programmer and bitoption; 02 system configuration masterwith one slave; 01 options ms connector (ms3102a); 1965 customer specific voltage/current configuration assigned by factory at time of order
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Detect cool test set
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
2000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
207.0 ac volts 1st alternate operating power rqmt and 253.0 ac volts 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
103.5 ac volts 2nd alternate operating power rqmt and 126.5 ac volts 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 440.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-0.1/+50.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit breaker and over current protector and over voltage protector and input voltage range switch
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Connector, receptacle single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Internal blower
MRC:
The program(s) for which the power supply is design compatible.CWWJ
Program Compatibility:
Ieee 488-1978
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
50.0