All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
b110026
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
005578262
NSN
National Stock Number:
6625-00-557-8262 6625005578262
TXT
Description:
Spectrum Analyzer
INC
INC
Item Name Code:
00833
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
23.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
19.594 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.062 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
110.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 0.05 kilohertz and 1.0 kilohertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+0.010/+40.880 gigahertz
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Attenuators, variable 3; bandpass filters 5; cable assemblies, rf 2; cable assembly, power 1; adapter, coaxial to waveguide 4; adapter, rf cable 1; carrying case 1; bracke, right hand 1; bracket, left hand 1; set of hand books cosisting of operating instrustrions
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current source.AMND
Input Impedance Rating:
50.0 ohms
MRC:
The number of specified ranges of frequencies or wavelengths operating between two stated limits.ANLC
Frequency Band Quantity:
8
MRC:
The limits of permissible variance from the standard/true value,expressed in percent.AREL
Frequency Calibration Accuracy Range In Percent:
-1.0/+1.0
MRC:
The information displayed on the cathode ray tube.BHZK
Cathode Ray Tube Displayed Information:
Displays each frequency component as power plotted against frequency
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver