Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Series rtw power supply
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.09 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.62 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.18 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Shock proof
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Unit 4025
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
200.0 ac volts and 240.0 ac volts 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
100.0 ac volts and 120.0 ac volts 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
12.0 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz and 66.0 hertz 1st operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-10.0 to 50.0 degrees celsius
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
150.0 watts single power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Square wave
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
12.5 dc amperes single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
1.0 ac amperes 2nd operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
1.9 ac amperes 1st operating power rqmt
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Is rohs compliant. Has the optional factory installed cover. Is modified by securing the four toroid transformers with epoxy to improve reliability under extraordinary shock or vibration conditions.