Input voltage adjustable in five increments from a high of 220.0 to 240.0 vac, greater than 196.0 vac, greater than 184.0 vac, greater than 172.0 vac, to a low of 160.0 vac to compensa te for brownout conditions; input lineuses an iec 320 male appliance coupler; option switches allow for customization of transfer voltage (on battery) in a stepped approximation to sine wave at 225.0 vac plus or minus 5 percent, set alarm, and control output frequency settings; unit has 4 iec female appliance couplers; ambient operating humidity plus 0.0 to 95.0 percent (non-condensing); hot swappable user-replaceable batteries; weighs 7.0 kg; low voltage directive 73/23/eec, gs licenses by vde per standard en60950 and en50091; emc directive 89/336/eec, c-tick approved, en5022 (cispr22) and en50082-1

NSN
National Stock Number:
6130-01-465-1969 6130014651969
TXT
Description:
Power Supply
INC
INC
Item Name Code:
00740
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
330.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
150.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
90.0 millimeters
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
3000.0 meters
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
0.5 multiple power outputs w/identical ratings
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
240.0 ac pounds per hour with retaining chain single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
225.00 ac volts multiple power outputs w/identical ratings
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz multiple power outputs w/identical ratings and 60.0 hertz multiple power outputs w/identical ratings
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+30.0 degrees celsius
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Current limit multiple power outputs w/identical ratings and voltage adjustment multiple power outputs w/identical ratings
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
300.0 watts multiple power outputs w/identical ratings
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Battery charger and calibrated output signal and circuit breaker and circuit overload protection device and emi filter and input voltage range switch and over current protector and voltage adjustment
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
500.0 ac volt-ampere multiple power outputs w/identical ratings
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single multiple power outputs w/identical ratings
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Limiting current multiple power outputs w/identical ratings
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 multiple power outputs w/identical ratings
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Rechargeable lead acid cell
MRC:
Indicates the location of the battery.CWJF
Battery Location:
Internal
MRC:
The time required to charge a battery(ies) to its rated capacity after a period of discharge.CWWB
Battery Recovery Time:
300.0
MRC:
The number of power supplies controlled by a programmable power supply.CXNJ
Power Supplies Programmed Per System:
4