Part Number BS-10100T-132P-SSTL

Sediment Strainer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
bs-10100t-132p-sstl
Demil:
No
Shelf Life:
UOM:
NIIN:
014407425
NSN
National Stock Number:
4730-01-440-7425 4730014407425
TXT
Description:
Sediment Strainer
INC
INC
Item Name Code:
04200
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Inlet connection top side and outlet connection top side
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
7.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
8.375 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Propulsion systems
MRC:
The length of a straight line which passes through the center of the opening,and terminates at the circumference.AKSV
Perforation Diameter:
0.031 inches
MRC:
A numeric value which represents the number of perforations contained in the item.AKSW
Perforation Quantity:
324.0 per square millimeter
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
75.0 degrees fahrenheit
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
150.0 pounds per square inch
MRC:
An indication of the structure or characteristic of the filtering media.CRXW
Filtering Media Design:
Any acceptable single filtering media response
MRC:
Indicates the type of connection on the first intake.CRXZ
First Intake Connection Type:
Threaded external pipe back
MRC:
The second intake connection relationship to the first intake connection.CRZD
Second Intake Connection Relationship To First Intake Connection:
Identical
MRC:
Indicates the first discharge connection relationship to an intake connection.CSJR
First Discharge Connection Relationship To Intake Connection:
Identical to first intake connection
MRC:
None.CSKY
Distance From Bottom Of Body To Center Of Inlet:
5.250 inches
MRC:
A designation distinguishing one group of thread diameter-pitch combination from another by the number of threads per measurement scale for a specific diameter.CTDY
First Intake Thread Series Designator:
Npt
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CTFF
First Discharge Thread Series Designator:
Npt
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CTFN
Second Intake Thread Series Designator:
Npt
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CTGB
Second Discharge Thread Series Designator:
Npt
MRC:
A designation that is used for the purpose of general identification of the thread.CTGK
First Intake Thread Size:
1.000 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CTLG
First Discharge Thread Size:
1.000 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CTMC
Second Intake Thread Size:
1.000 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CTQF
Second Discharge Thread Size:
1.000 inches
MRC:
The direction of the thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.CXPF
First Intake Thread Direction:
Right-hand
MRC:
The direction of the thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.CXRS
Second Intake Thread Direction:
Right-hand
MRC:
The direction of the thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.CXTT
Second Discharge Thread Direction:
Right-hand
MRC:
The direction of the thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.CXYG
First Discharge Thread Direction:
Right-hand
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 316 filtering medium or plastic filtering medium
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Any acceptable
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Diverted flow basket strainer w/bolted cover

Similar Sediment Strainers

« Hose, Pipe, Tube, Lubrication and Railing Fittings Catalog
Compare Now »
Clear | Hide