016082805

Part Information
Electyrochemica (co) sensor module, smart ed, 500ppm, 4r +

NSN
National Stock Number:
6665-01-608-2805 6665016082805
TXT
Description:
Gas Detector
INC
INC
Item Name Code:
37401
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Any acceptable
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Nsn 5180015637474
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Sensor known to have cross-sens.To gas other than target
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Chemical reaction
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Pressure range: atmospheric +/- 10%; drift: <2% signal/month; 2yr in air operating life; cal. Flow rate: 150cc/min; humidity operating 15-90% non-condensing; range 0-500ppm
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Presents specification, cross-sens. & calabration info.
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Resolution: 1ppm; temp. Range -4f-122f (-20c-50c)