Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Electronic Chopper
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
7
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug/stud
MRC:
The provision/s/ for mounting the item.ABDR
Mounting Provision:
Holes
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
1.141 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.141 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.875 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.141 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+125.0 degrees celsius
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.140 in. Diameter mtg holes on 0.861 by 0.861 in. Mtg centers
MRC:
Indicates the type of coil used.APAG
Coil Type:
Not isolated
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, double throw, one position momentary
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
6.3 ac pounds per hour wet
MRC:
Indicates the type of unit.APQB
Unit Type:
Electromechanical
MRC:
Designates the size of the mounting facility.AWYX
Mounting Facility Size:
0.140 in. Dia
MRC:
The means of attaching the item.AXGY
Mounting Method:
Hole
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Provided
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Equal
MRC:
An indication of whether the output voltage is the same as,or different from,the input voltage.BGRH
Output/input Voltage Relationship:
Equal
MRC:
Indicates the type of reed provided.BGRJ
Reed Type:
Single
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Breaks before makes
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
10.0 dc pounds per hour with retaining chain
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
1.0 milliamperes
MRC:
The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
Phase Angle In Deg:
57.0
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
170.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Not provided
MRC:
The style designation indicating the configuration that most nearly corresponds to the wiring of the base connection.BGRX
Base Connection Wiring Style:
7 pin standard tube