Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
c2741withcenterstud
NSN
National Stock Number:
TXT
Description:
Electronic Chopper
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
7
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Tube plug
MRC:
The provision/s/ for mounting the item.ABDR
Mounting Provision:
Studs
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.250 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.750 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
6625-00-753-2114 voltmeter
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
0.125 in. Diameter 40 thd per in. 0.625 in. Lg thd stud
MRC:
Indicates the type of coil used.APAG
Coil Type:
Isolated
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, double throw
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
10.0 dc pounds per hour wet
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
10.0 ac volts
MRC:
Indicates the type of unit.APQB
Unit Type:
Electromechanical
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
Between 1.0 hertz and 180.0 hertz
MRC:
The output current rating at which the item is designed to operate.AQYD
Output Current Rating:
1.0 milliamperes
MRC:
Designates the size of the mounting facility.AWYX
Mounting Facility Size:
0.112 in. Diameter by 0.625 in. Lg
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded stud mtd
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Provided
MRC:
The amount of input current for which the item is rated.AZSL
Input Current Rating:
1.0 milliamperes
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Unequal
MRC:
The value,or range of values,for which the drive is rated.BGRC
Drive Voltage Rating:
6.3 ac pounds per hour wet
MRC:
An indication of whether the drive current is the same as,or diffrent from,the input current.BGRD
Drive Current Relationship To Input Current:
Unequal
MRC:
The amount of current for which the drive is rated.BGRF
Err Default:
Err default
MRC:
The number of complete cyclic changes,per unit of time,for which the drive is rated.BGRG
Drive Frequency Rating:
Between 1.0 hertz and 180.0 hertz
MRC:
An indication of whether the output voltage is the same as,or different from,the input voltage.BGRH
Output/input Voltage Relationship:
Unequal
MRC:
Indicates the type of reed provided.BGRJ
Reed Type:
Single
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Breaks before makes
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
10.0 dc pounds per hour with retaining chain
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
1.0 milliamperes
MRC:
The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
Phase Angle In Deg:
15.0 and 20.0
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
Between 43.0 and 47.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Not provided
MRC:
The style designation indicating the configuration that most nearly corresponds to the wiring of the base connection.BGRX
Base Connection Wiring Style:
7 pin standard tube