Part Number C4344-23-3

Thermostatic Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
c4344-23-3
Demil:
No
Shelf Life:
UOM:
NIIN:
005386841
NSN
National Stock Number:
5930-00-538-6841 5930005386841
TXT
Description:
Thermostatic Switch
INC
INC
Item Name Code:
00451
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.328 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.640 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Internal sensor
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -65.0 degrees fahrenheit and 550.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, normally open, momentary action
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
1.0 amperes resistive load first voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
5.0 amperes resistive load second voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
5.0 amperes resistive load third voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point not adjustable
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
25.00 actuation point degrees celsius
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
250.0 ac at sea level first voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
30.0 ac at sea level second voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
30.0 dc at sea level third voltage

Similar Thermostatic Switches

« Switches Catalog
Compare Now »
Clear | Hide