Part Number C4736-2

Ventilating Fan

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
c4736-2
Demil:
No
Shelf Life:
UOM:
NIIN:
008138718
NSN
National Stock Number:
4140-00-813-8718 4140008138718
TXT
Description:
Ventilating Fan
INC
INC
Item Name Code:
04262
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
4.680 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
1.500 inches
MRC:
The direction in which the fluid is passed through the item.ADNK
Flow Direction:
Reversible
MRC:
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
Ambient Tempurature At Full Rated Power:
72.0 degrees celsius
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
3160.0
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Terminal
MRC:
The static pressure measured at the air flow rate specified.AJLY
Static Pressure At Specificationified Air Flow Rate:
0.0 inches of water
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 flange
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Clockwise and counterclockwise
MRC:
The rated capacity of air flow moved through the item.CQKX
Air Flow Rate:
100.0 cubic feet per minute
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
28.0 dc
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
0.003 horsepower
MRC:
None.CWLX
Housing Inside Diameter:
4.220 inches
MRC:
Indicates the type of bearing/s/ provided on the prime mover drive shaft.CWLY
Prime Mover Drive Shaft Bearing Type:
Sleeve
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
4.680 inches
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyolefin housing
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic phenolic blade
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Fixed
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81755-c4736-2 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)