Part Number C5NN13N313A

Thermal Flasher

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
c5nn13n313a
Demil:
No
Shelf Life:
UOM:
NIIN:
003509233
NSN
National Stock Number:
5945-00-350-9233 5945003509233
TXT
Description:
Thermal Flasher
INC
INC
Item Name Code:
08410
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.375 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.125 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Terminal mtd
MRC:
An indication of whether or not the item is adjustable.APCS
Adjustability:
Nonadjustable
MRC:
An indication of the number of flashes per time interval.APFH
Flashing Rate:
2 per second
MRC:
The number of circuits controlled by the item.APFP
Controlled Circuit Quantity:
1
MRC:
The amount of power a circuit can safely consume or provide.APFQ
Wattage Rating Per Circuit:
300.0 watts
MRC:
An indication of whether or not a facility for battery operation is provided.APFS
Battery Operation Facility:
Not provided
MRC:
The number of lamps for which the item is designed.APGQ
Lamp Quantity For Which Designed:
3
MRC:
An indication of whether or not an operating mechanism inclosure is included.APHC
Operating Mechanism Inclosure:
Not included

Similar Thermal Flashers

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide