Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
caqi310a
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
000687175
NSN
National Stock Number:
6625-00-068-7175 6625000687175
TXT
Description:
Spectrum Analyzer
INC
INC
Item Name Code:
00833
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.375 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 1000.0 hertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+0.001/+1.500 megahertz
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current source.AMND
Input Impedance Rating:
Between 30.0 kilohms and 100.0 kilohms
MRC:
The number of specified ranges of frequencies or wavelengths operating between two stated limits.ANLC
Frequency Band Quantity:
1
MRC:
Indicates the type of unit.APQB
Unit Type:
Standard
MRC:
The limits of permissible variance from the standard/true value,expressed in percent.AREL
Frequency Calibration Accuracy Range In Percent:
-1.0/+1.0
MRC:
An indication of the minimum to maximum scale of the meter.BHZH
Meter Scale Range:
10uv to 100v full
MRC:
The acceptable limits of deviation from the designed standard output value of the meter,expressed in percent.BHZJ
Meter Accuracy Range In Percent:
-6.0/+6.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-3.3
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Separates various frequency components of an input signal so they may be analyzed; functions as a tuned voltmeter for the measurement of relative or absolute signal levels & as a signal source for selective response measurements; also serves as an am receiver or carrier insertion oscillator for the demodulation of single sideband signals
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
76-10-01
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Hewlett packard co, 1976 catalog, page 439
MRC:
Indicates the relationship,such as construction,capabilities,and the like,of the item to a similar item.RTSE
Relationship To Similar Equipment:
When exhausted use 6625010121071
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Analyzer, spectrum, except specially designed

Similar Spectrum Analyzers