Part Number CF-30LWPDZ2M

Electronic Digital Data Analyzer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
cf-30lwpdz2m
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
015874209
NSN
National Stock Number:
6625-01-587-4209 6625015874209
TXT
Description:
Electronic Digital Data Analyzer
INC
INC
Item Name Code:
46820
INC
COM
Compliance:
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts 1st alternate operating power rqmt
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
240.0 volts 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz 2nd alternate operating power rqmt
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Alternate operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included 3rd operating power rqmt
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Video
MRC:
The number of alternating current phases.FAAZ
Phase:
Single 1st alternate operating power rqmt
MRC:
The number of alternating current phases.FAAZ
Phase:
Single 2nd alternate operating power rqmt
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used as a controller for aircraft line replaceable units, mission preparation, maintenance, retrieve encrypted mission critical data to up and down load line replaceable units

Similar Electronic Digital Data Analyzers

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide