Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Circuit Breaker Box
MRC:
Indicates the type of system in which the item is designed to be used.AGEJ
System For Which Designed:
Three wire single phase
MRC:
The maximum current rating of the main line,expressed in amperes.BFYC
Main Line Maximum Current Rating In Amps:
70.0
MRC:
The maximum alternating current voltage rating of the main line,expressed in volts.BFYD
Main Line Maximum Ac Voltage Rating In Volts:
240.0
MRC:
Indicates the type of ground connection for which the item is designed.BGJH
Ground Connection Type For Which Designed:
Solid
MRC:
Indicates the type and number of circuit breakers provided.BGJL
Circuit Breaker Type And Quantity:
6 single pole
MRC:
The maximum electrical current which the circuit breaker will carry without interrupting the circuit,expressed in amperes.BGJM
Circuit Breaker Current Rating In Amps:
15.0
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Cover
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular, surface mounting