Part Number CN3-1281-P

Laboratory Centrifuge

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
cn3-1281-p
Demil:
No
Shelf Life:
UOM:
NIIN:
011634213

Part Information
Centrifuge laboratory: table top 120/230v 50/60 hz

NSN
National Stock Number:
6640-01-163-4213 6640011634213
TXT
Description:
Laboratory Centrifuge
INC
INC
Item Name Code:
17093
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
433.0 millimeters
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
574.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
386.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
578.0 millimeters
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz and 60.0 hertz
MRC:
The means used to operate the item.APHE
Operation Method:
Electric
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
2700.0
MRC:
An indication of whether or not a guard bowl is included.ATPT
Guard Bowl:
Included
MRC:
Controls furnished which are not specified elsewhere.ATPW
Furnished Controls:
Timer, tachometer, brake and on/off switch
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0 or 230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Removable guard bowl; deployable medical item-electrical characteristics and provisioning
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
4 place horizontal rotor w/4 corrosion-resisting steel cups; equipped w/2 color coded test tube adapters with a capacity of twenty-four 13x100 mm tubes; four color coded test tube adapters with a capacity of eighteen 16x125 mm tubes; timer reading a of 30 minutes; speed selector ranging up to 6000 rpm; tachometer reading a of 6000 rpm in 200 rpm increments; variable or high/low brake; safety cover interlock system; unbalance sensor

Similar Laboratory Centrifuges

« Laboratory Equipment and Supplies Catalog
Compare Now »
Clear | Hide