Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Inavy timer, delay relay plug-in; output ratings: 7.5 amps, 1/3hp@240vac; 10 amps, 1/6hp@120vac; 200, 000 full load electrical cycles; 10, 000, 000 mechanical cycles; ambient temperature operating: -10 to +65 degree celsius; packaging: dust cover; weight: 7oz
NSN
National Stock Number:
TXT
Description:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.800 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
E/i panel, battery back-up 437-7383816-a1; wsd: virginia class submarine, ssn-774
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
Between 50.0 and 60.0
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 terminal single mounting facility
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
2 pole, double throw, double break/double make, one position momentary
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.05 seconds fixed release time and 0.50 seconds fixed release time
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
115.0 volts ac 40 degrees celsius single winding
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 110.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 pin all functions