Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Corrosion resistant; shell size 17
NSN
National Stock Number:
TXT
Description:
Electrical Receptacle Connector
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight shape threaded
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
32.5 millimeters
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
44.5 millimeters
Distance From Mounting Shoulder To Front Face:
22.6 millimeters
Mounting Facility Thickness:
2.2 millimeters
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
5 1st mating end
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Externally threaded coupling ring
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Fixed winged aircraft c130j
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back 1st mating end 1st contact grouping
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Pin 1st mating end 1st contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the shell is fabricated.CSPT
Shell Material:
Aluminum and stainless steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.CSWM
Shell Surface Treatment:
Cadmium
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
5 1st mating end 1st contact grouping