Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
d946-1-6m1
Demil:
No
Shelf Life:
UOM:
NIIN:
006430088
NSN
National Stock Number:
6110-00-643-0088 6110006430088
TXT
Description:
Motor Starter
INC
INC
Item Name Code:
00905
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
20.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.000 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Semiautomatic
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
1
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Six 9.16 in. Diameter mtt holes, 3 holes in ea row spaced 4-3/4 in. Apart, 17 in. Between rows
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Reduced
MRC:
The means used to reduce the electrical voltage.ANCP
Voltage Reduction Method:
Resistor
MRC:
The means used to restore the item to its full voltage.ANCQ
Full Voltage Restoring Method:
Counter emf acceleration
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
1.500
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
230.0 dc
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Overload and undervoltage
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
50.0 degrees celsius
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit protection fuse
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Ancy