Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Expansion Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Bronze
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
C1 straight thru
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 12
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACLG
First End Pipe Size Accommodated:
0.750 inches
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Piston, spring loaded
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The minimum to maximum pressures at which the item may be adjusted.ADSW
Adjustable Pressure Range:
+70.0/+260.0 pounds per square inch
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
42.000 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
2.000 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.250 inches
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Thermostatic
MRC:
A designation of the evaporator temperature range at which the valve is designed to operate.AFKL
Valve Evaporator Tempurature Range Designation:
Low
MRC:
An indication of whether or not a device is included that throttles or stops the flow of liquid,gas,and the like,through the valve when evaporator suction pressure reaches the maximum pressure setting.AFKM
Valve Pressure Limiting Device:
Not included
MRC:
Indicates the type of transfer agent contained in the thermostatic bulb which reacts to temperature change.AFKQ
Bulb Media Type:
Refrigerant 12
MRC:
The means utilized to hold the bulb in position.AFKR
Bulb Mounting Method:
Well
MRC:
Indicates whether the equalizer location is internal,external,or both.AFKU
Valve Equalizer Location:
Internal