Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Tinput control signal proportional 4.0 to 20.0 milliamps; shorted scr (silicon controlled rectifier) alarm; fan cooled; 0.0 to 90.0 percent relative humidity, non-condensing; storage temperature minus 40.0 to plus 85.0 degrees c
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
146.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
194.1 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
83.0 millimeters
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
3000.0 meters
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack or panel
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
277.0 ac pounds per hour dry single operating power rqmt and 600.0 ac pounds per hour with retaining chain single operating power rqmt
MRC:
Indicates the type of load for which the item is designed.ASCX
Load Type:
Resistive single power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
4 single power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Coarse current adjustment single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Current regulator circuit and ground wire terminal and indicator light and voltage adjustment
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Three single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
20 single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
55.0 ac amperes single operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Screw single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
3 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Single fan