Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
dubnoffshakingincubator
Part Information
Shaking speed 30-150 strokes/min
NSN
National Stock Number:
TXT
Description:
Bacteriological Incubator
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
23.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
21.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
15.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
11.125 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
15.750 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
4.250 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Gassing hood 3, oxygen/nitrogen flowrator assembly 1
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
870.0 watts
MRC:
Indicates the type of control.AQZF
Control Type:
Heater selector switch and motor switch and pilot light and thermometer and thermostat and flowmeter
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+25.0/+100.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Gravity
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
An indication of whether or not cooling coils for below room temperature use are included.BNDW
Cooling Coils For Below Room Tempurature Use:
Not included
MRC:
The element,compound,or mixture of which the cabinet outer wall is fabricated,excluding any surface treatment.BQMH
Cabinet Outer Wall Material:
Steel, stainless
MRC:
The element,compound,or mixture of which the cabinet inner wall is fabricated,excluding any surface treatment.BQMJ
Cabinet Inner Wall Material:
Steel, stainless
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
1
MRC:
An indication of whether or not an outer door insulation feature is included.BQMR
Outer Door Insulation Feature:
Not included
MRC:
An indication of whether or not a vacuum chamber is included.BQWN
Vacuum Chamber:
Not included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single