Part Number E500B

Radiacmeter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
e500b
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
005957479
NSN
National Stock Number:
6665-00-595-7479 6665005957479
TXT
Description:
Radiacmeter
INC
INC
Item Name Code:
07833
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.375 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means of attaching the item.ADJH
Mounting Method:
Portable
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays detects and beta rays measures and gamma rays detects and gamma rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Geiger tube
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+2000.0 milliroentgens
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0 to 2000.0 milliroentgens
MRC:
The minimum and maximum number of single responses per minute.APPK
Count Range Per Minute:
Not rated
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-15.0/+15.0 at full scale
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-15.0 to 15.0 at full scale
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Not rated
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
Not rated
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
3.0 dc