Part Number F400S

Calibrated Flow Valve

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
f400s
Demil:
No
Shelf Life:
UOM:
NIIN:
001581229
NSN
National Stock Number:
4820-00-158-1229 4820001581229
TXT
Description:
Calibrated Flow Valve
INC
INC
Item Name Code:
33212
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydraulic oil
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Flare
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
0.250-18 nptf
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACMQ
Second End Thread Size And Series/type Designator:
0.250-18 nptf
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
Second End Thread Direction:
Right-hand
MRC:
The angle of the end surface upon which the mated surface seats,expressed in degrees.ACTE
First End Seat Angle In Deg:
45.0
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Needle
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
5.0 gallons per minute
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
1st stage manual, 2nd stage automatic
MRC:
The means used to manually adjust the item.AEVP
Manual Control Method:
Knob
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
5000.0 pounds per square inch
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -25.0 degrees fahrenheit and 120.0 degrees fahrenheit

Similar Calibrated Flow Valves

« Nonpowered Valves Catalog
Compare Now »
Clear | Hide