Part Number FC50400UL

Static Frequency Converter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
fc50400ul
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
002336223
NSN
National Stock Number:
6930-00-233-6223 6930002336223
TXT
Description:
Static Frequency Converter
INC
INC
Item Name Code:
00330
INC
COM
Compliance:
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
14.500 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
17.250 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four no. 1/4-20 thd holes on 12.250 in. By 13.625 in. Mtg centers
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
0.5
MRC:
An indication of the accuracy of an item,expressed in percent.APFN
Accuracy In Percent:
0.01
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
Between 47.0 hertz and 63.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
400.0 hertz
MRC:
The means of attaching the item.AXGY
Mounting Method:
Base
MRC:
The amount of apparent power,as distinguished from true power,for which the item is rated.BGQS
Volt-ampere Rating:
500.0 volt-ampere
MRC:
The total line to line output alternating current potential for which the item is rated.BGQT
Line To Line Ac Output Voltage Rating:
132.0 volts
MRC:
The value,or range of values,of alternating current potential for which the input of an item is rated.BGQW
Ac Input Voltage Rating:
Between 108.0 volts and 132.0 volts
MRC:
An indication of whether or not overload protection is provided.BGQX
Overload Protection:
Not provided
MRC:
An indication of whether or not a radio interference filter is provided.BGQY
Radio Interference Filter:
Not provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
6.875 inches

Similar Static Frequency Converters

« Operation Training Devices Catalog
Compare Now »
Clear | Hide