Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Radio Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
12.500 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
15.312 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
Between 11.5 volts and 15.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Cord, ac power 8 ft; cord, dc power 6 ft; attenuator; antenna; cable; manual
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
8
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Faa
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
2-002978-001 part no. And 2-002979-001 part no. And rfa20 model no. And 2-003408-001 part no. And 1-003408-001 part no. And 1-910003-001 part no. And 1-500783-006 part no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum housing
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Power; freq; modulation; visual
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Freq 100 khz/500 mhz leveled; 50 hz/5khz, 500 mhz/1 ghz unleveled; freqresolution variable decade 10 hz equals 1/2 division; variable decade 0/1 khz; 1 khz decade 0/10 khz; 10 khz decade 0/100 khz; 100 khz decade 0/1 mhz; freq accuracy synthesized m0.0001 pct 1 ppm minus 5 deg/p50 degrees c
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
8.750 inches