Part Information
Aluminum surfaces treated with chemical film conversion process iaw mil-c-5541, class 1a and paint color balck; flanges whall mate with m3922/62-001 iaw mil-f-3922; 3.0 db porm 0.25 db coupling; coupling variation shall track within 0.25 db of the power coupled; 20.0 db min isolation; m90.0 db rf leakage; wave guide shall be m85/1-054 iaw mil-w-85; m46 to p85 degrees c operating temp range; 10, 000 ft altitude operating range; test rqmt for altitude, temperature, shock, vibration, humidity, salt spray and fungus, environmentals per mil-std-202 and mil-std-810 exc matl used in the device shall be nonutrient to fungus; reliability of the unit shall have a useful operating life of at least 10 years and 500, 000 hours per mil-hdbk-217; test procesures and test data for elec tests shall be supplied to the procuring activity for approval