Part Number G452477-1

Oscilloscope

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
g452477-1
Demil:
No
Shelf Life:
UOM:
NIIN:
013674237

Part Information
Provides 1000 cm/us stored writing speed; this nsn consists of 1 7b80 opt 2 dual time base, 6625010817818, & 2 7a22 differential amplifiers, 6625004780597, & 1 tektronix r7633 oscilloscope mainframe, 6625010891888

NSN
National Stock Number:
6625-01-367-4237 6625013674237
TXT
Description:
Oscilloscope
INC
INC
Item Name Code:
00357
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
22.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.300 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 100.0 volts and 240.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
1
MRC:
The interval/s/ as indicated by the markings on the item.AWEC
Graduation Interval:
Graduated v/cm both axis
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rack
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
8 by 10 division graticule w/additional graticule for reduced scan mode
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+0.2/+100000000.0 hertz
MRC:
An indication of whether or not a trigger sweep polarity switch is included.BGSB
Trigger Sweep Polarity Switch:
Included
MRC:
An indication of whether or not an expanded sweep is provided.BGSD
Expanded Sweep:
Provided
MRC:
The value,or range of values,for which the vertical deflection sensitivity is rated.BHDF
Vertical Deflection Sensitivity Voltage Rating:
10.0 microvolts peak to peak per centimeter and 10000000.0 microvolts peak to peak per centimeter
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Provided
MRC:
The total opposition (resistive and reactive) which the item offers to the y-axis input flow of alternating current.BHDX
Y-axis Input Impedance Rating:
1.0 megohms
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Sine wave
MRC:
The peak to peak value for which the item is calibrated.BHFB
Calibrating Peak To Peak Amplitude:
4.0 volts
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of the function of the plug in units and the number provided.BHFS
Plug In Unit Function And Quantity:
7a22 vertical amplifier 2, 7b80 opt 2 dual time base 1

Similar Oscilloscopes

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide