Part Number G5A-234P-DC12

Hybrid Relay

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
g5a-234p-dc12
Demil:
No
Shelf Life:
UOM:
NIIN:
016120966

Part Information
Contact ratings: 60vac, 0.5a; 720 ohm coil resistance; bifurcated crossbar contact type

NSN
National Stock Number:
5945-01-612-0966 5945016120966
TXT
Description:
Hybrid Relay
INC
INC
Item Name Code:
31445
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.4 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.9 millimeters
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0 to 70.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
C-10256c/brr-6 trident, cont ind
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
12.0 volts coil
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Double pole, double throw
MRC:
The amount of current for which the item is designed.AXNP
Current Rating:
16.7 milliamperes coil
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
1.1 milliseconds release
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
2.4 milliseconds operate
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Alloy contacts gold
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 pin

Similar Hybrid Relaies

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide