Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.730 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.396 inches single mounting facility and 1.446 inches single mounting facility
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.625 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.280 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.150 inches single mounting facility
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The purpose for which the item is designed.AKSL
Purpose For Which Designed:
General
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The means of quenching an arc.APNQ
Arc Quenching Method:
Air
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 slotted hole single mounting facility
MRC:
The number and combination(s) of the basic contact forms,in the order of assemblage,which make up the switching structure of the pile-up main contacts.AYSC
Pile-up Main Contact Form Arrangement:
2c
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
4.650 cubic inches
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Rectangular single mounting facility
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
150.0 milliamperes dc single winding
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
2.00 minutes fixed operate time
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
26.0 volts dc 25 degrees celsius single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 wire hook all functions