Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
80.000 in h, 66.000 in d, 168.000 in l; 14760.0 lbs
NSN
National Stock Number:
TXT
Description:
Hydraulic System Comp Test Stand
MRC:
The amount of hydraulic fluid required to operate the item.AAYJ
Hydraulic Fluid Flow Rate:
70.0 gallons per minute
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Hydraulic motor
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Aircraft hydraulic system
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Fixed
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
15000.0
MRC:
An indication of whether or not an accumulator is included.AYJM
Accumulator:
Included
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
5000.0 pounds per square inch
MRC:
The maximum pressure at which the item is designed to operate.BJDW
Maximum Operating Pressure:
5000.0 pounds per square inch
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Included
MRC:
The rated flow capacity of the item.CGYL
Flow Capacity Rating:
85.0 gallons per minute
MRC:
An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
Pressure Manifold Subcircuit:
Not included
MRC:
An indication of whether or not a filtering system is included.CHGQ
Filtering System:
Included
MRC:
An indication of whether or not a pressure and suction hose are included.CHGR
Pressure/suction Hose:
Included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
110.0 and 220.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Designed to provide accurate, functional and performance testing of aircraft hydraulic fixed and variable pumps, hydraulic motors, valves, actuating cylinders, reservoirs, and accumulators
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O. 33a2-2-35-11