Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Insulation Breakdown Test Set
MRC:
Indicates the type of termination provided on the wire.ABCC
Wire Termination Type:
Alligator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
343.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
244.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
292.0 millimeters
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Case and portable
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Dc
MRC:
An indication of the type of meter.ANTH
Meter Type:
Ammeter and voltmeter
MRC:
The number of meters provided.ANTJ
Meter Quantity:
1 and 1
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+2000.0 milliamps and +0.0/+15.0 kilovolts
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
Between 0.000 kilovolts and 15.000 kilovolts
MRC:
The output current rating at which the item is designed to operate.AQYD
Output Current Rating:
Between 0.000 milliamperes and 10.000 milliamperes
MRC:
Indicates the type of indicator used to show a leakage condition.AQYK
Leakage Indicator Type:
Meter
MRC:
The number of test leads provided with the item.AQYL
Test Lead Quantity:
3
MRC:
The device provided to protect the circuit from an electrical overload condition.AQYM
Circuit Overload Protection Device:
Circuit breaker and output current limiting circuit
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-1.3
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
92-07-16