Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Monitor output (agc) 2.3 vdc at less than minus 50 dbm, plus 3 vdc at minus 36 dbm, plus 10 vdc at minus 25 dbm
NSN
National Stock Number:
TXT
Description:
Intermediate Frequency Amplifier
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+20.0/+2000.0
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
200.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-32.0/+75.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
750.000 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
100.0 megahertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
200.0 megahertz operating channel err-100
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
11.0 milliwatts output
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
2.0 volts
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
Shock Pulse Duration Time:
1.0 milliseconds
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 single voltage
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Automatic gain control
MRC:
The number of hertz /cycles per second/ expressing the difference between the limiting frequencies at which the desired fractions /usually half power/ of the maximum output is obtained.CMGX
Intermediate Frequency Bandpass:
100.0 megahertz
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Tests to be performed at vendor facilities with all test data available for inspection; stabilization bake, 24 hours at 150 degrees centigrade; temp cycle minus 55 degrees centigrade to plus 125 degrees centigrade; burn-in test 160 hours at 85 degrees centigrade; elec test at plus 25 degrees centigrade