Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Tank heating units are used for heating water and are specifically engineered for installation in water storage tanks, the heating medium may be either steam or hot water
NSN
National Stock Number:
TXT
Description:
Steam-hot Water Hea Water Heater
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
150.0 pounds per square inch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
112.000 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
54.000 inches
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Horizontal
MRC:
Items furnished as accessories which are not specified elsewhere.AFJH
Furnished Items:
Superior glass-lined tank, asme code section 5 constructed, all bronze circulator, all copper recirculation with two bronze ball valves, flush mounted t and p gauges, national board stamped, 3 inches fiber glass insulation, galvanized baked enamel jacket, asme t and p valve, heating coil section 8 of asme code
MRC:
The rated heating capacity of the item per hour.AMHR
Heating Capacity Per Hour:
303.0 gallons
MRC:
Indicates the capacity of the tank.AMKA
Tank Capacity:
700.0 gallons
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water inlet connection.AMLL
Water Inlet Connection Thread Size And Series/type Designator:
3in npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water outlet connection.AMLM
Water Outlet Connection Thread Size And Series/type Designator:
3in npt
MRC:
The number of water inlet connections.AMLQ
Water Inlet Connection Quantity:
1
MRC:
The number of water outlet connections.AMLR
Water Outlet Connection Quantity:
1
MRC:
The maximum pressure at which the heating coil is designed to operate.AMRE
Heating Coil Maximum Operating Pressure:
303.0 pounds per square inch
MRC:
An indication of the surface area of a heating coil.AMRF
Heating Coil Surface Area:
10.3 square centimeters
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil inlet connection.AMRG
Err Default:
Err default
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil outlet connection.AMRH
Err Default:
Err default
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Glass
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Glass
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Enamel, baked