Part Number IEG6-IREC4-61-15.0-21-V

Circuit Breaker

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
ieg6-irec4-61-15.0-21-v
Demil:
No
Shelf Life:
UOM:
NIIN:
015177229

Part Information
Operates in m40.0-85.0 degrees c; insulation resistance not less than 100 megohms at 500 volts dc; dielectric strength withstands 3750 vac, 60 hz for 60 seconds between all electricity isolated terminals, except auxiliary switch terminsal shall withstand 600 vac, 60 hz for reg and rec types; operating as a switch the operating life exceeds 10, 000 operations at a rate of 6 per minute when tested as follows 6000 ops at rated current plus 4000 ops at no load; electrical characteristics 0.050-50 amperes; 80vdc max, 240vac max, 50/60 hz and 0.050-30 amperes; 250vac max, 400 hz; one toggle handle per unit; handle color red

NSN
National Stock Number:
5925-01-517-7229 5925015177229
TXT
Description:
Circuit Breaker
INC
INC
Item Name Code:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single pole type
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.750 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.075 inches
MRC:
None.AJEC
Boss Height:
0.240 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 single location or 60.0 single location
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Pct overload-trip time in seconds 100 pct no trip, 125 pct 0.7-12, 150 pct 0.35-7, 200 pct 0.130-3, 400 pct 0.030-1, 600 pct 0.015-0.3, 800 pct 0.01-0.15, 1000 pct 0.008-0.1
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
Mil-std-202 standard (includes industry or association standards, individual manufactureer standards, etc.).