Part Number IM181APD

Radiacmeter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
im181apd
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
001488054
NSN
National Stock Number:
6665-00-148-8054 6665001488054
TXT
Description:
Radiacmeter
INC
INC
Item Name Code:
07833
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.500 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.530 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Clip
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Anodized
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Provided
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Optical quartz fiber electrometer
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
X-rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Ionization chamber
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+1000.0 milliroentgens
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0 to 1000.0 milliroentgens
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Not rated
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
Not rated