Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Thermal Resistor
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.500 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.220 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.175 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.025 inches
MRC:
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
Ambient Tempurature At Full Rated Power:
25.0 degrees celsius
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
150.0 degrees celsius
MRC:
The ratio,at a specified ambient temperature,of a change in power dissipation in an item to the resultant body temperature change,expressed in milliwatts per degree celsius.AEJB
Power Dissipation Constant In Milliwatts Per Deg Celsius:
8.5
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-21.5 degrees celsius 2nd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-55.0 degrees celsius 1st resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
104.4 degrees celsius 5th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
25.0 degrees celsius 3rd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
37.8 degrees celsius 4th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
250.0 ohms 4th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
27.0 kilohms 1st resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
3.7 kilohms 2nd resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
30.7 ohms 5th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
412.0 ohms 3rd resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-10.0/+10.0 4th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-15.0/+15.0 3rd resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-20.0/+20.0 2nd resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-20.0/+20.0 5th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-30.0/+30.0 1st resistance-temperature point
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encapsulated
MRC:
The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.CQWD
Zero Power Resistance:
412.000 ohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.CRQJ
Zero Power Resistance Tolerance In Percent At Reference Temp:
-15.0/+15.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Disk
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead