Part Number LB125

Electrical Load Bank

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
lb125
Demil:
No
Shelf Life:
UOM:
NIIN:
009584173
NSN
National Stock Number:
6150-00-958-4173 6150009584173
TXT
Description:
Electrical Load Bank
INC
INC
Item Name Code:
33776
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
28.500 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
50.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
120.0 volts and 240.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 208.0 hertz and 480.0 hertz
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Electrical load
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Power range 90kw to 180kw
MRC:
The number of alternating current phases.FAAZ
Phase:
Three and single/three
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-12.9
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Completely self contained test unit designed to provide electrical loadtesting of engine/generator sets at unity power factor; can be used to adjustgovernors, fuel systems, voltage regulators, testing switchgears &generator output capability & acceptance tests
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
43.000 inches
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
80-12-15
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
33aa7-57-21-1