Part Number LE458-0001-4006

Electrical Solenoid

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
le458-0001-4006
Demil:
No
Shelf Life:
UOM:
NIIN:
012870698
NSN
National Stock Number:
5945-01-287-0698 5945012870698
TXT
Description:
Electrical Solenoid
INC
INC
Item Name Code:
00310
MRC:
The minimum and maximum pitch diameter limits of a straight screw thread.AAJE
Thread Pitch Diameters:
+1.214/+1.217 inches mounting facility bushing
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Enclosed frame
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.880 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 3.000 inches and 3.530 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof
MRC:
The identifying numeric code of the originator that controls or manufactures the electrical connector receptacle.AEEE
Connector Manufacturer Code:
43999
MRC:
The identifying part number assigned to the electrical connector receptacle.AEEF
Connector Manufacturer Part Number:
Le458-0001-4006
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
265.0 degrees fahrenheit
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
Between 1.410 inches and 1.470 inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
Between 0.350 inches and 0.410 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
B-1b aircraft
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
2
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Circumference
MRC:
The value of electrical energy for which the item is rated.ARQE
Electric Power Rating:
5.0 watts
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
Between 18.0 dc and 33.0 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded bushing
MRC:
The amount of current for which the item is designed.AXNP
Current Rating:
250.0 milliamperes
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
9.799 cubic inches
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
20 mounting facility bushing
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Pull
MRC:
The amount of linear force delivered.CNXW
Linear Force Delivered:
18.00 pounds
MRC:
Indicates the type of means provided for connection of the power takeoff.CNXX
Power Takeoff Connection Type:
Clevis tongue
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
1.125 inches mounting facility bushing
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Mounting stud shall be pinned to prevent rotation
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Uns mounting facility bushing
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead

Similar Electrical Solenoids

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide