Part Number LS-34768-368633

Liquid Level Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
ls-34768-368633
Demil:
No
Shelf Life:
UOM:
NIIN:
011707371

Part Information
2nd float effective travel 12.875 in. Min, 13.125 in. Max, 3rd float effective travel 7.875 in. Min, 8.125 in. Max, 4th float effective travel 6.875 in. Min, 7.125 in. Max

NSN
National Stock Number:
5930-01-170-7371 5930011707371
TXT
Description:
Liquid Level Switch
INC
INC
Item Name Code:
37187
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
54.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
120.0 volts
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
240.0 volts
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
50.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
120.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
240.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
50.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
5.562 inches
MRC:
The identifying numeric code of the originator that controls or manufactures the electrical connector receptacle.AEEE
Connector Manufacturer Code:
04034
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Connector receptacle
MRC:
The specification,standard,or manufacturer's number or symbol used to identify the connector.AGBG
Connector Identification:
34770
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
0.2 amperes resistive load
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
50.0 volts
MRC:
The number of floats provided.AWAE
Float Quantity:
4
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -65.0 degrees fahrenheit and 250.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The maximum continuous current which must not be exceeded in order to avoid damage to the item.BJKC
Maximum Current Rating:
1.0 amperes resistive load
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Spst, normally open, normally closed
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Hydraulic oil and lubricating oil and sea water and various fuels and water
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
Between 21.375 inches and 21.625 inches
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
Six 0.562 in. Diameter holes equally spaced on a 4.438 in. Diameter bolt circle
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
Between 51.438 inches and 51.562 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Liquid Level Switches

« Switches Catalog
Compare Now »
Clear | Hide