Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
m-23548e3r
Demil:
No
Shelf Life:
UOM:
NIIN:
015119402
NSN
National Stock Number:
5950-01-511-9402 5950015119402
TXT
Description:
Power Autotransforme Transformer
INC
INC
Item Name Code:
36166
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.500 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz single component or 60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Three phase to three phase single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
100.0 amperes ac single component single secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
33.0 k1lovolt-amperes single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
110.00 ac pounds per hour dry single component single secondary and 190.00 ac pounds per hour with retaining chain single component single secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
120.00 ac pounds per hour dry single component single primary and 208.00 ac pounds per hour with retaining chain single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 terminal block w/screws