Part Number M5562917HQHQHQ

Circuit Breaker

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
m5562917hqhqhq
Demil:
No
Shelf Life:
UOM:
NIIN:
014971625

Part Information
Circuit breaker has three pole, single throw normally open switch contact arrangement; mount in vertical plane

NSN
National Stock Number:
5925-01-497-1625 5925014971625
TXT
Description:
Circuit Breaker
INC
INC
Item Name Code:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Multipole-multiple actuator type
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
5.125 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.108 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
Between 3.480 inches and 3.614 inches
MRC:
The center to center distance between terminals parallel to the width of the item.AEBQ
Center To Center Distance Between Terminals Parallel To Width:
Between 0.996 inches and 1.056 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.750 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.026 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Weapon launch console assembly for losangeles class submarine 688
MRC:
None.AJEC
Boss Height:
0.220 inches
MRC:
None.AJWX
Mounting Surface To Terminal End Distance:
Between 3.460 inches and 3.580 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
3
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
6 threaded hole
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
25.0 amperes ac all locations
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations
MRC:
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
250.0 ac all locations
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Overcurrent all locations
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Magnetic all locations
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay all locations
MRC:
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
1000.0 all locations
MRC:
The ultimate time per pole in which the device must trip,expressed in seconds.CPRP
Ultimate Trip Time Per Pole In Seconds:
0.800 all locations and 7.000 all locations
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Trip free
MRC:
Indicates the type and number of actuators provided for manual control.CPRT
Manual Actuator Type And Quantity:
3 toggle
MRC:
Denotes the action imparted by actuator operation.CPRW
Actuator Function:
Trip-reset
MRC:
An indication of the designated position of the actuator.CPRX
Actuator Position Designation:
At each pole
MRC:
Indicates the arrangement of the externally connected actuators.CPRY
External Actuator Linkage Arrangement:
One, two, and three linked
MRC:
The function for which the auxiliary switch is designed and the number provided.CPRZ
Auxiliary Switch Function And Quantity:
1 alarm
MRC:
The basic internal electrical configuration of the trip mechanism.CPSM
Internal Trip Release Configuration:
Series trip all locations
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches
MRC:
Indicates the location of the switch in relation to its designated position.CQSM
Switch Location And Position Designation:
Internal at pole one
MRC:
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
Trip Delay Time In Seconds Per Rated Continuous Current:
0.150 at 200 pct all locations and 1.000 at 200 pct all locations and 0.032 at 400 pct all locations and 0.250 at 400 pct all locations and 0.110 at 800 pct all locations
MRC:
Indicates the type of protection for which the inclosure is designed.CQXF
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant and salt water resistant
MRC:
Indicates the type of terminal for providing electrical connection to the switch.CRTK
Switch Terminal Type:
Pin
MRC:
The amount of current,expressed in amperes,and the type for which the switch is rated.CSSX
Switch Current Rating And Type In Amps:
5.0 ac and 1.0 dc
MRC:
The voltage,expressed in volts,and current type for which the switch is rated.CSWP
Switch Voltage Rating And Type In Volts:
250.0 ac and 50.0 dc
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 all locations
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 threaded stud
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-55629/17 government specification

Similar Circuit Breakers

« Circuit Breakers Catalog
Compare Now »
Clear | Hide