Part Number MA7525S003

Radio Frequency Transmiss Switch
Description

5985000117532. Radio frequency transmiss switch has an overall length of 3.94 inches.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
ma7525s003
Demil:
No
Shelf Life:
UOM:
NIIN:
000117532
NSN
National Stock Number:
5985-00-011-7532 5985000117532
TXT
Description:
Radio Frequency Transmiss Switch
INC
INC
Item Name Code:
05298
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.940 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.810 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.810 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz single frequency operating and 2.0 gigahertz single frequency operating0.0 gigahertz single frequency rf power handling and 2.0 gigahertz single frequency rf power handling0.0 gigahertz single frequency voltage standing wave ratio and 2.0 gigahertz single frequency voltage standing wave ratio0.0 gigahertz single frequency insertion loss reference and 2.0 gigahertz single frequency insertion loss reference0.0 gigahertz single frequency crosstalk reference and 2.0 gigahertz single frequency crosstalk reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 2.0 gigahertz single frequency operating0.0 gigahertz and 2.0 gigahertz single frequency rf power handling0.0 gigahertz and 2.0 gigahertz single frequency voltage standing wave ratio0.0 gigahertz and 2.0 gigahertz single frequency insertion loss reference0.0 gigahertz and 2.0 gigahertz single frequency crosstalk reference
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.180 inches
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Transfer
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.437 inches single mounting facility pattern
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.20 single
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.20 single
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Tnc
MRC:
The design of the connector end.AHUD
Connector End Design:
Male
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
100.0 watts average single
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
80.0 single
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Relay
MRC:
The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
Actuator Current Type And Rating In Amps:
0.1 ac
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
115.0
MRC:
An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
Switch Operation Sequence:
Breaks before makes
MRC:
The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
Switch Return Mechanism Type:
Fail-safe
MRC:
The maximum radio frequency voltage that the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration.AKQA
Rf Maximum Voltage Rating:
500.0 volts peak
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
4
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line single mounting facility pattern
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Body and connector surfaces rhodium and body and connector surfaces silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Rhodium and silver
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Rhodium body outside surfaces and silver body outside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Rhodium connecto (s) outside surfaces and silver connector(s) outside surfaces
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 connector, receptacle and 4 receptacle, coaxial

Similar Radio Frequency Transmiss Switches

« Antennas, Waveguides and Related Equipment Catalog
Compare Now »
Clear | Hide