Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Rotary Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
Duty Cycle In Percent:
100
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
15.000 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
200.000 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Single
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The position of the gas cooling equipment whether between stages /intercooler/,after the last stage /aftercooler/,or both.AAXU
Gas Cooling Equipment Type:
Air type aftercooler and air type intercooler
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
7.000
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wheel
MRC:
The mechanical action by which compression takes place.AAYB
Rotary Compressor Design:
Sliding vane
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
2
MRC:
The speed of the compressor required to produce its rated capacity,expressed in revolutions per minute.AAYS
Compressor Speed At Rated Capacity In Rpm:
Not rated
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded female
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded female
MRC:
Indicates a device used to eliminate the noise of the intake or discharge of the item.AAZA
Silencer Type:
Discharge
MRC:
A measurement of the longest dimension of an item unencumbered by packaging or packing,in distinction from width.AJAF
Unpackaged Unit Length:
72.50 inches
MRC:
A measurement taken at right angles to the length of an item unencumbered by packaging or packing,in distinction from thickness.AJAG
Unpackaged Unit Width:
41.75 inches
MRC:
A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
Unpackaged Unit Height:
50.50 inches
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of control device provided.BDML
Control Device Type:
Automatic start-stop
MRC:
Indicates the type of safety device(s) provided.BPRZ
Safety Device Type:
Relief valve
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Fungus resistant treatment
MRC:
Indicates the type and amount of electrical flow at which the item is designed to operate,expressed in amperes.CQJY
Current Type And Rating In Amps:
14.0 ac and 7.0 ac
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
230.0 ac or 460.0 ac
MRC:
The degree of heat or cold as applied to the function of the item.CSFH
Tempurature Rating Per Function:
Not rated
MRC:
The brake power required to start and operate the item including all accessories at the actual rated capacity,expressed in unit of power.CXNT
Brake Power Required:
7.000 horsepower
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to provide a source of compressed air for operating paint spraying equipment and inflating tires
MRC:
The measured weight of an item unencumbered by packaging or packing material.PKWT
Unpackaged Unit Weight:
735.00 pounds
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Af to. 34y1-64-1
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
Mb-2 type