Part Number MDR-4091

Rotary Relay

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
mdr-4091
Demil:
No
Shelf Life:
UOM:
NIIN:
011238307
NSN
National Stock Number:
5945-01-123-8307 5945011238307
TXT
Description:
Rotary Relay
INC
INC
Item Name Code:
03890
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.130 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.625 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.196 in. Diameter mtg holes spaced on 2.125 in. By 2.125 in. Mtg centers
MRC:
The basic structure of the item.ALXF
Structural Design:
Nonpile-up
MRC:
The alternating current values of root mean square potential which must be applied to the item for operation,expressed in volts.ANWD
Ac Operating Voltage Rating In Volts:
440.0
MRC:
The operating current for which the item is rated.APAM
Operating Current Rating:
20.0 milliamperes
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac and dc
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
125.0
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
800.0 milliamperes resistive
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
10.0 amperes
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
115.0
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
12
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
4
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Clockwise
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
4.5 kilohms
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
4pdt
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
2
MRC:
An indication of the characteristic(s) of a winding.CPWM
Winding Characteristic:
Single wound untapped
MRC:
The measurement of the shaft rotation,expressed in degrees.CPWT
Shaft Rotation In Deg:
30.0

Similar Rotary Relaies

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide