Part Number MIL-B-16041

Ready-cut Prefabricated Building

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
mil-b-16041
Demil:
No
Shelf Life:
UOM:
NIIN:
002544278

Part Information
Designed for ammunition storage, door louvers and ventilators equipped w/spark and missile screens

NSN
National Stock Number:
5410-00-254-4278 5410002544278
TXT
Description:
Ready-cut Prefabricated Building
INC
INC
Item Name Code:
02393
MRC:
A nominal measurement taken at right angles to the length of an item,in distinction from thickness.AKGF
Width:
25.000 feet
MRC:
A nominal measurement of the longest dimension of an item,in distinction from width.AKGG
Length:
48.000 feet
MRC:
The element,compound,or mixture of which the floor is fabricated,excluding any surface treatment.AQJL
Floor Material:
Concrete
MRC:
Indicates the location of the door on the item.AYXP
Door Location:
End wall
MRC:
Indicates the type and number of doors furnished with the item.BGDY
Door Type And Quantity:
2 hinged double
MRC:
Indicates the location of an item which is insulated.BNJD
Insulation Location:
Uninsulated
MRC:
Indicates the location of the door opening.BPQL
Door Opening Location:
End wall
MRC:
A measurement from floor level to center clearance of the item.BXDB
Err Default:
Err default and err default
MRC:
A measurement from floor level to center clearance of the item.BXDB
Center Inside Clearance Height:
Between 12.333 feet and 12.666 feet
MRC:
An indication of whether or not a partially paneled feature is included.BXDJ
Partially Paneled Feature:
Not included
MRC:
The element,compound,or mixture of which the roof frame is fabricated,excluding any surface treatment.BXDL
Roof Framing Material:
Steel
MRC:
The element,compound or mixture of which the roof is fabricated,excluding any surface treatment.BXDN
Roof Material:
Steel
MRC:
The element,compound,or mixture of which the sidewall frame is fabricated,excluding any surface treatment.BXWP
Sidewall Framing Material:
Steel
MRC:
The element,compound,or mixture of which the outside sidewall is fabricated,excluding any surface treatment.BXWQ
Outside Sidewall Material:
Steel
MRC:
The element,compound,or mixture of which the inside sidewall is fabricated,excluding any surface treatment.BXWR
Inside Sidewall Material:
Steel
MRC:
The element,compound,or mixture of which the endwall frame is fabricated,excluding any surface treatment.BXWS
Endwall Framing Material:
Steel
MRC:
The element,compound,or mixture of which the outside endwall is fabricated,excluding any surface treatment.BXWT
Outside Endwall Material:
Steel
MRC:
The element,compound,or mixture of which the inside endwall is fabricated,excluding any surface treatment.BXWW
Inside Endwall Material:
Steel
MRC:
The element,compound,or mixture of which the floor frame is fabricated,excluding any surface treatment.BXWX
Floor Framing Material:
Concrete
MRC:
The element,compound,or mixture of which the foundation post(s) is fabricated,excluding any surface treatment.BXWY
Err Default:
Err default
MRC:
The element,compound,or mixture of which the foundation post(s) is fabricated,excluding any surface treatment.BXWY
Foundation Post Material:
Steel
MRC:
The element,compound,or mixture of which the ceiling is fabricated,excluding any surface treatment.BXXC
Err Default:
Err default
MRC:
The element,compound,or mixture of which the ceiling is fabricated,excluding any surface treatment.BXXC
Ceiling Material:
Steel
MRC:
The element,compound,or mixture of which the partition(s) is fabricated,excluding any surface treatment.BXXD
Err Default:
Err default
MRC:
The element,compound,or mixture of which the partition(s) is fabricated,excluding any surface treatment.BXXD
Partition Material:
Any acceptable
MRC:
The number of rooms provided.BXXF
Room Quantity:
1
MRC:
The number of door openings provided.BXXG
Err Default:
Err default
MRC:
The number of door openings provided.BXXG
Door Opening Quantity:
1
MRC:
Indicates the type of door opening provided.BXXH
Err Default:
Err default
MRC:
Indicates the type of door opening provided.BXXH
Door Opening Type:
Frame
MRC:
A measurement taken at right angles to the length of the door uprights.BXXJ
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the door uprights.BXXJ
Door Opening Width:
8.000 feet
MRC:
A measurement from the bottom to the top of the door opening,in distinction from depth.BXXK
Err Default:
Err default
MRC:
A measurement from the bottom to the top of the door opening,in distinction from depth.BXXK
Door Opening Height:
10.000 feet
MRC:
A measurement taken at right angles to the length of the door.BXXL
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the door.BXXL
Door Width:
4.000 feet
MRC:
A measurement from the bottom to the top of the door,in distinction from depth.BXXM
Err Default:
Err default
MRC:
A measurement from the bottom to the top of the door,in distinction from depth.BXXM
Door Height:
10.000 feet
MRC:
The number of louver openings provided.BXXX
Err Default:
Err default
MRC:
The number of louver openings provided.BXXX
Louver Opening Quantity:
2
MRC:
The number of louvers provided.BXXY
Louver Quantity:
2
MRC:
The number of ventilator openings provided.BXXZ
Err Default:
Err default
MRC:
The number of ventilator openings provided.BXXZ
Ventilator Opening Quantity:
3
MRC:
The number of ventilators provided.BXYB
Ventilator Quantity:
3
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Barrel type arch

Similar Ready-cut Prefabricated Buildings

« Prefabricated and Portable Buildings Catalog
  • 1585950
    NSN: 5410-00-262-4671
  • P300A
    NSN: 5410-00-267-8898
  • S-78/G
    NSN: 5410-00-281-5283
  • S57GR
    NSN: 5410-00-281-5284
  • CSC359
    NSN: 5410-00-285-7882
Compare Now »
Clear | Hide