Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Indicator, rate of flow, 0-5, 000 pph, integrally lighted
NSN
National Stock Number:
TXT
Description:
Rate Of Flow Indicator
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
2.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
6.125 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
12
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Rate of flow
MRC:
Indicates the type of presentation.AMNL
Presentation Type:
Dial
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+5000.0 pounds per hour single indicator single scale
MRC:
An indication of the individual marking on the item.ASKN
Individual Marking:
Fuel flow; pph x 1000
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
8202-13-12pm-pp or mc14h-13-12pn or equivalent
MRC:
The function for which the pointer is intended.ASSR
Pointer Purpose:
Indicate current rate of flow
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Indicating single pointer
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 clamp
MRC:
An indication of the accuracy of an item.BNHZ
Accuracy Rating:
100.0 pounds per hour single indicator single scale
MRC:
The length of a straight line which passes through the center of the dial,and terminates at the outside circumference.CXQH
Dial Outside Diameter:
1.750 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Pcase conforms to ms33639 and is hermetically sealed; case finish lusterless black per color no. 37038 of fed-std-595; includes filler tube; power consumption 8.0 va; weight 1.5 lbs; integral lighting per mil-l-27160
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Indicator designed to indicate the rate of flow in pounds per hour when connected with a tru-6/a fuel flow transmitter conforming to mil-t-26298